华为昇腾设备管理
Huawei Ascend NPU natural language management skill, supporting both local direct connection and SSH remote modes. Provides comprehensive npu-smi command capabilities including device queries, configuration management, firmware upgrade, vNPU virtualization, certificate management, and compute power testing (FLOPS). Enables remote management and monitoring of Ascend NPU devices with real-time metrics tracking. Use this skill when the user wants to: (1) query NPU device status and health, (2) monitor temperature, power, memory/HBM utilization, (3) configure ECC settings and fan modes, (4) perform firmware upgrades or rollbacks, (5) manage vNPU virtualization, (6) run compute power tests, (7) check certificate information. Trigger: user mentions 'npu', 'ascend', 'NPU', 'Ascend', 'temperature', 'power', 'HBM', 'firmware', 'upgrade', 'vNPU', 'virtualization', 'certificate', 'FLOPS', 'compute', 'health', 'memory', 'utilization', 'ECC', 'fan', '昇腾', '昇腾卡', '昇腾状态', '显存', '算力', '设备查询', 'NPU监控'
在 Tokeny 中使用「华为昇腾设备管理」
- 下载 Tokeny 客户端
- 一键安装此技能
- 直接在对话中使用
在电脑上打开此页面
Tokeny 是桌面客户端,请在 Windows、macOS 或 Linux 电脑上打开此页面下载。
SKILL.md
Natural language command translation and execution for Huawei Ascend NPU devices: device queries, configuration management, firmware upgrade, vNPU virtualization, certificate management, and compute power testing.
Overview
Translates natural language requests into npu-smi / ascend-dmi commands on Huawei Ascend NPU devices, over either a local direct connection or an SSH remote session. This is a stateless, operational skill: it stores no credentials, device state or conversation history between invocations.
Capabilities: device queries (health, temperature, power, HBM, ECC, topology) · configuration (ECC, fan mode/speed) · firmware version / upgrade / activate / rollback · vNPU virtualization · TLS certificate management · FLOPS testing.
Orchestration: the Agent invokes this skill alongside others when a task needs them — for example a general-purpose SSH remote-operations skill (disk, Docker, logs, processes) or a model-deployment skill whose NPU state is monitored after deploy. Skills never call each other directly; the Agent selects and chains them from user intent. See references/architecture.md.
Prerequisites
| Requirement | Detail |
|---|---|
| Python | 3.8+ (python3 --version) |
| Local mode | npu-smi (CANN) on the local machine; ascend-dmi additionally for FLOPS tests |
| SSH remote mode | paramiko — install with pip install -r requirements.txt (paramiko>=2.11,<4) |
| Target host | Reachable network, running sshd, password authentication enabled |
- Local mode needs no Python package beyond the standard library.
- SSH mode needs
paramiko; it is imported lazily, so local mode still works when it is absent. - The target machine must have CANN/
npu-smiinstalled — runnpu-smi infothere once to confirm. - Security: never read, echo or print password values; never ask the user to paste a password into the conversation; read credentials only from the
--passwordcommand-line argument.
Core Workflow
- Parse the user intent and normalize Chinese trigger words (触发词: 温度 / 功耗 / 显存 / 算力 / 固件 / 虚拟化 / 风扇 / 启用 / 禁用 …) to English.
- Direct passthrough first: if the input starts with
npu-smi, execute it verbatim — this precedes natural-language routing, sonpu-smi info -lkeeps its-l. - Route the natural-language request to a handler and resolve the device target (
NPU0 Chip0), defaulting to NPU 0 / Chip 0. - Read-only queries execute immediately and are formatted for the user.
- Write operations print a confirmation gate and wait for
confirm/确认(orcancel/取消) before executing — see Parameter Confirmation. - Any failure returns a structured
[ERROR] NPU-*response; a Python traceback is never shown.
python3 scripts/main.py --command "NPU health check" # one-shot
python3 scripts/main.py --command "查看NPU温度" # Chinese trigger words
python3 scripts/main.py --command "NPU list" --host <ip> --user root --password <pwd> # SSH remote
python3 scripts/main.py # interactive
Core Commands
| Intent | Example input | Underlying command |
|---|---|---|
| List devices | NPU list | npu-smi info -l |
| Full / card info | NPU info | npu-smi info (full NPU information) |
| Card / chip mapping | NPU chip mapping, chip list | npu-smi info -m (card-to-chip mapping) |
| Direct passthrough | any input starting with npu-smi, e.g. npu-smi info -t board | executed verbatim, exactly as typed — passthrough takes precedence over natural-language routing |
| Health check | NPU health check | npu-smi info -t health -i 0 |
| Temperature / power / memory / usage | NPU temperature, 功耗, 显存 | npu-smi info -t temp | power | memory | usages -i 0 -c 0 |
| ECC direction (mandatory) | set ECC enable, disable ECC | npu-smi set -t ecc-enable -i 0 -c 0 -d 1 | 0 (confirmation) |
| Fan mode | set fan auto, set fan manual | npu-smi set -t pwm-mode -d 1 | 0 (confirmation) |
| Fan speed | set fan speed 70 | npu-smi set -t pwm-duty-ratio -d 70 (confirmation) |
| Firmware version / upload | firmware version, upgrade firmware | npu-smi upgrade -b mcu -i 0 / upgrade -t mcu -i 0 -f <file>.hpm (confirmation) |
| Firmware activate | activate firmware, activate upgrade mcu NPU0 | npu-smi upgrade -a <component> -i 0 (confirmation) |
| Firmware rollback | rollback firmware | npu-smi upgrade -a rollback -i <npu_id> (confirmation) |
| vNPU | vNPU info, template info, create vNPU, destroy vNPU | npu-smi info -t info-vnpu | template-info …, set -t create-vnpu | destroy-vnpu … (confirmation) |
| Certificate | certificate info, cert expiration | npu-smi info -t tls-cert | tls-cert-period -i 0 -c 0 |
| FLOPS | FLOPS test, FP32 FLOPS, all devices FLOPS | ascend-dmi -f -d <n> -t <fp16|fp32|bf16|int8|hf32> -q; multi-device runs async in parallel |
The complete natural-language → command mapping lives in references/command-mapping.md.
Parameter Confirmation
| Parameter | Required | Description |
|---|---|---|
--command | Yes (one-shot) | Natural language request, or a direct npu-smi command |
--host | SSH mode | Remote host IP address / hostname |
--user, --password | SSH mode | SSH credentials (password authentication only) |
Read-only queries never prompt. These write operations always print their exact effect and wait for confirm / 确认 before executing:
- ECC enable/disable — the direction (
enable/disable) is mandatory;set ECCwith no direction is answered with a clarification question and nothing is executed. - Fan mode / fan speed —
set fanwith neitherauto/manualnor a speed value is answered with a clarification question; it never defaults to a speed. - Firmware upload / activate / rollback — rollback may be unsupported by some devices.
- vNPU create / destroy.
- Certificate management.
Output Format
Query results are human-readable text, optionally followed by the structured JSON envelope:
{"status": "success", "command": "npu-smi info -l", "description": "List all NPU devices"}
Errors use exactly three lines, with CODE taken from the error-code contract below:
[ERROR] <CODE>
Message: <error-description>
Suggestion: <troubleshooting-tip>
Error Handling & Stability
Error-code contract. One code per failure class, so "wrong credentials", "wrong host" and "the remote host really has no NPU" stay distinguishable:
| Code | Meaning | Typical suggestion |
|---|---|---|
NPU-SSH-AUTH | SSH authentication failed | check --user / --password, account lockout, password login allowed |
NPU-SSH-UNREACHABLE | host unreachable, port refused or connect timeout | check host, port 22, network, security group, sshd |
NPU-SSH-ERROR | other SSH-level failure | retry once, then inspect sshd logs on the target |
NPU-CMD-NOT-FOUND | npu-smi / ascend-dmi not installed or not on PATH | install CANN/npu-smi on the target, or use --host for SSH mode |
NPU-CMD-FAILED | command ran but exited non-zero | inspect the reported exit code and stderr summary |
NPU-TIMEOUT | command exceeded its timeout | check device load, retry once if the condition was transient |
NPU-UNEXPECTED | unclassified fallback | check the command and environment, then retry |
Retry policy. Only transient failures are retried: a failing SSH connect/execute is retried once after the connection is closed, i.e. at most 2 attempts in total (worst-case wait ≈ 2 × connect timeout). Authentication failures, command_not_found, non-zero exits and timeouts are not retried blindly. Retries are always bounded and never fan out (no retry storm); a failed write is never silently re-sent.
Timeouts. SSH connection timeout 10s; a single local/remote command 60s; FLOPS tests up to 120s. Exceeding a timeout returns [ERROR] NPU-TIMEOUT with a suggestion instead of hanging.
Degradation. Every layer degrades to a friendly message rather than a traceback: missing npu-smi → NPU-CMD-NOT-FOUND; missing ascend-dmi → "ascend-dmi not found" for that FLOPS test only; missing paramiko or a failed SSH connection → a connection error, never "No NPU devices found". handle_command(None), non-string and empty input return the help listing instead of raising. See references/troubleshooting.md.
Idempotency. Queries (list, info, health, temperature, …) are read-only and safe to repeat. Writes (ECC, fan, firmware, vNPU, certificate) always pass the confirmation gate, execute exactly once, and are never auto-replayed after a failure — re-issue them explicitly if needed.
Boundary conditions.
- No NPU hardware / no
npu-smilocally → friendlyNPU-CMD-NOT-FOUND, not a stack trace. - SSH authentication failure, unreachable host, and a reachable host with genuinely zero devices must remain three distinct outcomes; a connection error is never parsed as an empty device list.
- Empty command output → an explicit "no data / no devices" message, never a crash.
- Chinese input (for example
查看NPU温度) is normalized to English before routing. - Multi-turn state is limited to the pending confirmation of the current invocation; nothing is persisted, so every invocation starts clean.
Dependencies. Local mode: npu-smi (CANN), plus ascend-dmi for FLOPS only — no Python package required. SSH mode: paramiko (pip install -r requirements.txt). When a dependency is missing, report its error code and suggestion; never invent a fallback command.
Verification Method
python3 --version→ 3.8+.python3 scripts/main.py --command "NPU list"→ a device table, or a friendlyNPU-CMD-NOT-FOUNDwhennpu-smiis absent (never a traceback).python3 scripts/main.py --host <ascend-ip> --user root --password <pwd> --command "NPU health check"→ remote status; a wrong host or password must yieldNPU-SSH-*, not "No NPU devices found".
The full reproducible matrix (Chinese inputs, direct npu-smi passthrough, confirmation gates, rollback) is in references/verification-method.md.
Troubleshooting
- Command not recognized → use a supported keyword; Chinese trigger words are normalized, but unsupported wording returns the help listing.
- SSH connection failed → follow the
[ERROR] NPU-*code: credentials and account state forNPU-SSH-AUTH, host / port / network /sshdforNPU-SSH-UNREACHABLE. npu-sminot available → install CANN/npu-smion the target machine and checkLD_LIBRARY_PATH.
Error codes and per-code diagnosis steps: references/troubleshooting.md.
Notes & Limitations
- Sensitive operations always require confirmation; blocked commands cannot be bypassed; passwords are held in memory for the session only.
- Requires
npu-smi(orascend-dmifor FLOPS) on the target machine; SSH uses password authentication only (no interactive prompt). - Verify a single card before batch operations, and watch temperature / HBM usage to avoid OOM.
- Architecture, Agent orchestration flow, script files and directory layout: references/architecture.md.
References
| Document | Description |
|---|---|
| architecture.md | System architecture, Agent orchestration flow, stateless rules, script files and directory layout |
| command-mapping.md | Complete natural-language → npu-smi / ascend-dmi command mapping, including fan mode/speed and firmware rollback |
| acceptance-criteria.md | Acceptance criteria for skill validation |
| verification-method.md | Reproducible verification steps and test methods |
| troubleshooting.md | Error codes and troubleshooting guide |
| device-queries.md | Device queries command reference |
| configuration.md | ECC and fan configuration reference |
| firmware-upgrade.md | Firmware version, upgrade, activate and rollback reference |
| virtualization.md | vNPU virtualization reference |
| certificate-management.md | Certificate management reference |
| iam-policies.md | IAM permission policy requirements (none — local/SSH operational skill) |
Technical Support
- Ascend official documentation: https://www.hiascend.com/document
- npu-smi command reference: https://www.hiascend.com/document/detail/zh/Atlas%20200I%20A2/260RC1/re/npu/npusmi_007.html
Tokeny 是什么
- 免费的桌面 AI 助手,支持 Windows、macOS 和 Linux。
- 说一句话就能处理文件、生成文档与表格、执行多步骤任务。
- 通过技能和 MCP 扩展能力,一键安装市场里的资源。
评论与讨论
还没有评论,分享你的体验吧。